Wind-chill numbers look like temperatures, which is why most developers treat them like temperatures in unit tests and UI validations. Then an input sits slightly outside the National Weather Service domain — either too warm or too calm — and the polynomial quietly extrapolates nonsense.
The NWS wind chill equation
In North America, wind chill is defined for air temperatures $T \le 50^\circ\text{F}$ ($10^\circ\text{C}$) and wind speeds $V > 3\ \text{mph}$ ($4.8\ \text{km/h}$):
$$\text{WC} = 35.74 + 0.6215\,T - 35.75\,V^{0.16} + 0.4275\,T\,V^{0.16}$$
Notice the fractional exponent $V^{0.16}$ and the interaction term $T\,V^{0.16}$. Unlike linear unit conversions, this formula is an empirical regression fitted to facial heat-loss measurements within that specific wind and temperature box.
Three boundary bugs to catch in code
1. Computing wind chill when V <= 3 mph
At $V = 1\ \text{mph}$, $1^{0.16} = 1$, so the formula yields $\text{WC} = 35.74 + 0.6215\,T - 35.75 + 0.4275\,T = 1.049\,T - 0.01$ — which can make $30^\circ\text{F}$ at near-calm wind report warmer than air temperature ($31.46^\circ\text{F}$), violating basic physics. You must clamp: if $V \le 3\ \text{mph}$ (or $T > 50^\circ\text{F}$), wind chill equals the air temperature itself.
2. Mixing metric inputs into US customary constants
The coefficients 35.74, 0.6215, 35.75, 0.4275 only work with Fahrenheit and mph. Passing Celsius and km/h into that polynomial without converting first (or switching to the Environment Canada metric coefficients 13.12 + 0.6215*T_c - 11.37*V_kmh^0.16 + 0.3965*T_c*V_kmh^0.16) silently corrupts every reading. Always enforce unit tags before calling Math.pow(v, 0.16).
3. Passing negative wind speeds
Negative V turns Math.pow(V, 0.16) into NaN in JavaScript because a fractional power of a negative real number is undefined. Reject or clamp V < 0 at validation time.
A concrete check
At $T = 20^\circ\text{F}$ and $V = 15\ \text{mph}$:
$V^{0.16} = 15^{0.16} \approx 1.5425$, giving $\text{WC} \approx 35.74 + 12.43 - 55.14 + 13.19 = 6.2^\circ\text{F}$.
If you want to verify both °F/mph and °C/km/h cases — including whether a tool properly returns raw air temperature outside the $50^\circ\text{F} / 3\ \text{mph}$ domain — Miryori's browser-side wind chill calculator exposes the active formula and unit conversion without uploading inputs.
Note: examples above illustrate numerical formula boundaries, not emergency weather guidance.